EXPERIMENTAL ANALYSIS OF THE EFFECT OF STRUCTURAL CHANGES IN GREENHOUSES WITH A DOUBLE-SLOPE ROOF

Authors

  • C. A. BOUZO Facultad de Ciencias Agrarias, Universidad Nacional del Litoral. Laboratorio de Investigaciones en Fisiología y Biología Molecular Vegetal (LiFiBVe), Kreder 2805. (3080). Esperanza, provincia de Santa Fe
  • M. P. LENSCAK Instituto de Investigación y Desarrollo Tecnológico para la Agricultura Familiar Región Pampeana. Villa Elisa, La Plata Buenos Aires

DOI:

https://doi.org/10.14409/fa.v17i1.7645

Keywords:

Greenhouse, structure, micrometeorology, temperature, ventilation-rate

Abstract

An experimental analysis of a two-slope greenhouse was carried out, to which dimensional modifications and design of the roof windows were made. Were compared the wind speed (m s -1 ), air flow rate (m 3 h -1 ), air temperature (oC) and vapor pressure deficit (kPa) in two greenhouses called here CMT and CMA. The work was developed in Goya, Corrientes, Argentina (29o 02’S, 59o 10’W) in the year 2016 in february, march and november months. A better micro-meteorological condition was observed in the CMA greenhouse, since it had a lower daytime internal temperature, higher wind speed, air flow and consequently a greater ventilation-rate. The results are discussed based on the dimensional and design differences of the greenhouses taking into account the results of other research works.

Published

2018-09-06

How to Cite